Residential Membrane Elements

Residencial Reverse Osmosis Membrane Series

Puroxy Residential Reverse Osmosis Membrane Series Can Effectively Remove All Kinds Of Impurities And Pollutants In Water, Such As Organics, Microorganism, Heavy Metal Ions, Etc. It Is Widely Applied In Residential Water Filters, Commercial Water Filters ,compact Water Vending Machines, Etc. It Is Large In Output Water Flow, High In Salt Rejection, Stable In Performance. What More, With Strong Research And Development Ability, Puroxy Is Able To Customize All Kinds Of Reverse Osmosis Membranes For Varies Purposes.

Specification And Main Performance Of Membrane Elements

Model Average Rejection Minimum Rejection Average Permeated Flow(GPD) Active Membrane Area ft2(M2)
RO-2012-75 97 95 75 0.36
RO-2012-80 97 95 80 0.38
RO-2012-100 97 95 100 0.54
RO-3012-300 97 95 300 1.65

Testing Conditions

Testing Pressure 70psi (0.48MPa)
*TW3012-400/TW3013-400 *90psi (0.6MPa)
Temperature of Testing Solution 25c
Concentration of Testing Solution 250ppm
pH value of Testing Solution 7.5
Recovery Rate 15%

Operation Limits and Conditions

Max. Working Pressure 300psi (2.07MPa)
Max. Working Feedwater flow 2gpm
Max. Feedwater Temperature 45c
Max. Pressure SDI 5
Max. Pressure Drop 15psi(0.1MPa)
Residual Chlorine Decline <0.1ppm
pH Range of Feedwater 3.0-10.0

Residential Nano Filtration Membrane

Residencial Membrane Series

Puroxy Residential Reverse Osmosis Membrane Series Can Effectively Remove All Kinds Of Impurities And Pollutants In Water, Such As Organics, Microorganism, Heavy Metal Ions, Etc. It Is Widely Applied In Residential Water Filters, Commercial Water Filters ,compact Water Vending Machines, Etc. It Is Large In Output Water Flow, High In Salt Rejection, Stable In Performance. What More, With Strong Research And Development Ability, Puroxy Is Able To Customize All Kinds Of Reverse Osmosis Membranes For Varies Purposes.

Specification And Main Performance Of Membrane Elements

Model Average Rejection Minimum Rejection Average Permeated Flow(GPD) Active Membrane Area ft2(M2)
NF-2012-150 60~70 60 150 0.36
NF-3012-300 60~70 60 300 1.65

Testing Conditions

Testing Pressure 90psi (0.62MPa)
Temperature of Testing Solution 25c
Concentration of Testing Solution 250ppm
pH value of Testing Solution 7.5
Recovery Rate 15%

Operation Limits and Conditions

Max. Working Pressure 300psi (2.07MPa)
Max. Working Feedwater flow 2gpm
Max. Feedwater Temperature 45c
Max. Pressure SDI 5
Max. Pressure Drop 15psi(0.1MPa)
Residual Chlorine Decline <0.1ppm
pH Range of Feedwater 3.0-10.0

Application